Description
Keeler, the first name in cryo surgery, has been supplying the ophthalmic surgeon with high-performance, reliable cryo systems since 1966. Changes in technology and the surgeons’ requirements have allowed us to improve and expand our range of cryo ophthalmic instruments. Keeler has over 40 years experience in offering ophthalmic cryo surgical units starting with the Amoils cryosurgical unit. Building on the exceptional reliability of its predecessors, the Cryomatic MK-II delivers automation and versatility. The Cryomatic MKII’s coupling system is compatible with a single-use or reusable probe without the need for an adaptor. The cryo console automatically detects the type of probe in use and adjusts internal parameters to reduce complexity and steps required to conduct ophthalmic cryosurgery. The 3.5″ backlit digital display and inbuilt speakers provide the user with intuitive cues such as freeze time, gas cylinder status and probe information.
The Cryomatic MKII console and probes can be considered a superior treatment than using laser retinopexy for the following cases:
- Treating peripheral retinal pathologies
- One-step procedure for retinal detachments. Laser retinopexy on the other hand, must be performed 24-48 hours after gas injection.
- Where there are obstructions within the eye limiting penetration of the laser, such as a cataract or vitreous opacity.
The Keeler Cryomatic MKII console is compatible with seven reusable probes which are used to treat a variety of pathologies. Keeler also offer a single-use probe reducing the need for sterilization and improving scalability. The Cryomatic console employs smart technology electronic communication between the console and any probe that is connected to it allows for optimum operating parameters for any given probe and self-adjustment. Put another way, the console auto-configures to probe characteristics. The main advantage of this is that there no longer is a need for manual setup at the start of or during any procedure. This also means that the gas pressure will always be set automatically – no manual adjustment needed.
Features:
Automation:
Keeler has been offering cryo surgical systems specifically for ophthalmic purposes for over 40 years. We have learned it is critical to reduce the number of variables when conducting cryotherapy. Therefore, the Cryomatic MKII allows the user to be set up within a matter of minutes. Gone are the days when users were required to adjust pressures to gain the optimum probe temperature; the Cryomatic MKII console automatically detects the probe and applies the most optimum pressure levels to enable optimum freezing of the pathology.
Compatibility with a range of probes:
The Keeler Cryomatic MKII is the one-stop solution for ophthalmic cryo surgery. The console is designed to be compatible with Keeler’s own reusable and single-use probes. Keeler’s range of reusable probes provide users with versatility to treat a range of pathologies, while the single-use probe has been designed hand-in-hand with end users to gain the best performance during retinal cryopexy procedures.
Compatible with both CO2 and N2O:
The Keeler Cryomatic MKII is compatible with either CO2 and N2O allowing the system to be versatile for a range of end-users and geographies.
- Gas compatibility: Medical grade CO2 or N2O
- Operating range: 3100-4480kPa/450-650PSI/31-45Bar
- Cylinder pressure: 8275kPa/1200PSI/83Bar
- Digital display size: 3.5″”
- W x D x H: 14″” x 8″” x 7.5″”
- Weight: 5kg/10lbs
- Complies with: EN60601-1, UL60601-1 and CAN/CSA-C22.2 No. 601-1
- Equipment Class: Class 1, type BF
Back-flush facility
During purging, and about 20 seconds after the footswitch is released, the gas in the system reverses its flow, but at a lower pressure. This changed direction of gas after a freeze moves any debris or moisture that may be accumulating, thereby virtually eliminating the risk of problems during surgery.
Perfection evolved
Building on the exceptional reliability of it’s predecessor, the Cryomatic MK II ophthalmic cryo machine delivers quality and versatility when using either disposable or reusable probes. The Cryomatic MK II’s new coupling system allows you to connect either a single use disposable or reusable probe without the need for an adaptor. The new integral software automatically detects the type of probe in use and adjusts the cryo unit accordingly, meaning the unit is ready for use in a matter of minutes.
With exceptional reliability, the Cryomatic delivers quality and versatility when using either disposable or reusable probes. The integral software automatically detects the type of probe in use and adjusts the unit accordingly, meaning the unit is ready for use in a matter of minutes. This technology ensures a short purge cycle time after time without the need for an adapter. Engineered to produce greater reliability and freezing characteristics. 12″W x 8″D x 7.5″H. Weighs 6 pounds
This Keeler Cryomatic Console MK-ll comes equipped with:
- Rolling Cryomatic Stand with 20 lb. Tank Holder
- (1) Standard Retinal Probe (2509-P-8000)
- 6 Month warranty
For more information, click brochure link: https://files.advancingeyecare.com/Keeler/cryomatic.pdf